Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
Baby changing station mounting height ada.
Where a forward reach in unobstructed the high forward reach shall be 48 inches 1220 mm maximum and the low forward reach shall be 15 inches 380 mm minimum above the finish floor or ground.
Five tips for ada compliance.
Any change to restroom functionality inevitably turns to the question of americans with disabilities act ada compliance.
Horizontal stainless steel recess mounted kb110 ssre.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
They have to be mounted so that the very top of the changing table surface when it is opened cannot be any higher than 34 inches off the floor she says.
Check your local code for addition information and requirements.
The ada requires 59 inches and 27 inches your manufacturer s instruction sheet should be consulted for recommended mounting heights.
Below is a diagram from diaper depot about mounting baby changing stations.
Install at the perfect height.
The americans with disabilities act ada was created to ensure access to buildings and structures for people with disabilities.
There are specific mounting heights and other requirements of baby changing stations in restrooms says ada compliance expert joan stein of stein consulting inc pittsburgh.
Figure 308 2 a forward reach.
The ada standards are issued by the department of justice doj and the department of transportation dot.
Complete the design by providing the required amount of toe clearance underneath the lavatory of 17 inches 430mm to 25 inches 635mm maximum.
Recess mounted stainless steel clad baby changing station is the premier choice for upscale restroom facilities.
Knee clearance must extend 25 inches under a changing table and the unit must be 9 inches above the finish of the ground.
When the unit s bed is opened and laid flat it must provide adequate knee clearance below the station.
For horizontal changing stations the ada requires that the unit protrude no more than 4 from the wall and be no higher than 27 inches from the floor.
Listed below are standards for baby changing stations.
Toe clearance at least 9 inches 230mm above the finish floor must be provided for the full depth.
Baby changing stations types.
Recess mounted plastic baby changing station with stainless steel flange is a stylish and safe option for restroom facilities.
Oval baby changing stations.
See figure s 308 2 a.
Protruding objects units are not to protrude more than 4 inches from the wall when closed.